Full Wave Rectifier

5AR4 Full Wave Rectifier The 5AR4 is a heater-cathode twin diode designed for full-wave rectifier opertion. High output current and small size make this tube especially suitable for compact amplifier designs. ELECTRICAL Cathode …………………………………………………………………………………………………… coated unipotential Heater Voltage AC or DC …………………………………………………………………………… 5. 0 ! 0% Volts Heater Current …………………………………………………………………………………………. 1. 9 Amps MECHANICAL Base ……………………………………………………………………………………………………….. Intermediate-Shell Octal 5 pin Bulb ………………………………………………………………………………………………………… T-9, 1 3/16″ max. dia. Max. overall length ……………………………………………………………………………………. 7/16 inch Max. seated height ……………………………………………………………………………………. 2 7/8 inch Max. diameter ………………………………………………………………………………………….. 1 9/32 inch Mounting Position ……………………………………………………………………………………… any RECTIFIER SERVICE – MAXIMUM RATINGS – Design Center Values Peak Inverse Plate Voltage ………………………………………………………………………… 700 Volts AC Plate-Suppl Voltage per Plate ……………………………………………………………….. See Rating Chart 1 Steady-State Peak Plate Current per Plate …………………………………………………… 825 mA Transient Peak Plate Current per Plate, Max. Duration 2 Seconds …………………… 3. 7 Amps DC Output Current ……………………………………………………………………………………. See Rating Chart 1 TERMINAL CONNECTIONS
Pin 1 Pin 2 Pin 4 Pin 6 Pin 8 Internal Connection Heater Plate Number 2 Plate Number 1 Heater and Cathode (Revised 6/3/99) P E N T A L A B O R A T O R I E S 9740 COZYCROFT AVENUE * CHATSWORTH * CALIFORNIA 91311 (800) 421-4219 * (818) 882-3872 * FAX: (818) 882-3968 ELECTRON TUBES FOR INDUSTRY 5AR4 Full-Wave Rectifier Design-Maximum values are limiting values of operating and environmental conditions applicable to a bogey tube of a specified type as defined by its published data, and should not be exceeded under the worst possible conditons.
The tube manufacturer chooses these values to provide acceptible servicability of the tube, taking responsibility for the effects of changes on operationg conditions due to variations in tube characteristics. The equipment manufacturer should design so that initially and throughout life no design-maximum value for the intended service is expected with a bogey tube under the worst possible conditions with respect to supply-voltage variation, equipment component variation, equipment control adjustment, load variation, signal variation, and environmental conditions.

Save Time On Research and Writing
Hire a Pro to Write You a 100% Plagiarism-Free Paper.
Get My Paper

FULL-WAVE RECTIFIER WITH CAPACITOR-INPUT FILTER AC Plate-Supply Voltage per Plate, RMS ………………………………………….. 450 Total Plate-Supply Resistance per Plate …………………………………………… 160 DC Output Current ………………………………………………………………………… 225 DC Output Votlage at Filter Input …………………………………………………….. 475 550 200 160 620 Volts Ohms mA Volts FULL-WAVE RECTIFIER WITH CHOKE-INPUT FILTER
AC Plate-Supply Voltage per Plate, RMS ………………………………………….. 450 Filter Input Choke ………………………………………………………………………….. 10 DC Output Current ………………………………………………………………………… 250 DC Output Votlage at Filter Input …………………………………………………….. 375 Tube Voltage Drop Ib=225 mADC per Plate……………………………………………………………… 7Volts 550 10 225 465 Volts Henrys mA Volts To simplify the application of the maximum ratings to circuit design, the Design-Maximum ratings are presented in a chart form as Ratings Charts 1, 2, and 3. Rating Chart 1 presents the maximum ratings for a-c plate supply voltage and d-c output current. Rating Chart 2 provides a convenient method for checking confornance with the steady-state peak-plate current rating. Rating Chart 3 offers a convenient method for checking conformance with the

Place your order
(550 words)

Approximate price: $22

Calculate the price of your order

550 words
We'll send you the first draft for approval by September 11, 2018 at 10:52 AM
Total price:
$26
The price is based on these factors:
Academic level
Number of pages
Urgency
Basic features
  • Free title page and bibliography
  • Unlimited revisions
  • Plagiarism-free guarantee
  • Money-back guarantee
  • 24/7 support
On-demand options
  • Writer’s samples
  • Part-by-part delivery
  • Overnight delivery
  • Copies of used sources
  • Expert Proofreading
Paper format
  • 275 words per page
  • 12 pt Arial/Times New Roman
  • Double line spacing
  • Any citation style (APA, MLA, Chicago/Turabian, Harvard)

Our Guarantees

Delivering a high-quality product at a reasonable price is not enough anymore.
That’s why we have developed 5 beneficial guarantees that will make your experience with our service enjoyable, easy, and safe.

Money-back guarantee

You have to be 100% sure of the quality of your product to give a money-back guarantee. This describes us perfectly. Make sure that this guarantee is totally transparent.

Read more

Zero-plagiarism guarantee

Each paper is composed from scratch, according to your instructions. It is then checked by our plagiarism-detection software. There is no gap where plagiarism could squeeze in.

Read more

Free-revision policy

Thanks to our free revisions, there is no way for you to be unsatisfied. We will work on your paper until you are completely happy with the result.

Read more

Privacy policy

Your email is safe, as we store it according to international data protection rules. Your bank details are secure, as we use only reliable payment systems.

Read more

Fair-cooperation guarantee

By sending us your money, you buy the service we provide. Check out our terms and conditions if you prefer business talks to be laid out in official language.

Read more

Online Class Help Services Available from $100 to $150 Weekly We Handle Everything